Class100, 000 Cleanroom for Many Industrial Sectors
Click image to view full size image
Product: Views:230Class100, 000 Cleanroom for Many Industrial Sectors 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-10-25 15:04
  Inquiry
Details
100,000-class Cleanroom definition
Definition
100,000 class cleanromm means 0.5μmdiameter the quantity of dust particles less than 100,000per cubic meter. 100,000-class refers to the quantity allowed to exist dust particles of less 0.5 microns control less than 100,000ps within a foot of space.

100,000 clean area standard 
according to the number of dust particles and to define the number of microorganisms
1.The maximum number of dust particles (per cubic meter) to allow:
Large or equal to the number of particles of 0.5 microns less 3.5 million,
A large number of particles or equal to 5 microns less than 20,000;
2.The maximum allowable number of microorganisms:
Planktonic bacteria not more than 500 per cubic meter:,
Settlement of bacteria not more than 10 per dish.
USA Federal Standard 209E(1992 Year)
Clean standard Particle size(um)
  0.1 0.2 0.3 0.5 5    
100000 NA NA NA 100000 700    
 Units: quntity of dust/ft3 
 China pharmaceutical manufacturing clean room (area) of air cleanliness standard
Clean standard quntity of dust/M3  Maximum allowable quantity of microorganisms
  ≥0.5um ≥5um Float bacteria PS/M3 Subsidence bacteria PS/.30min
100000 3,500,000 20,000 500 10      
China Drug Administration of August 1, 1999 issued and implemented






 